Error code Fault Reason
11000-2 EEPROM: Abnormal MC failure
11001-2 RAM abnormality MC failure
11002-2 A/D converter abnormality MC failure
11003-3 Abnormal sensor voltage MC fault/ Induction fault/ Wire harness fault

Hitachi ZX470-5G Direct Injection Excavator Error Code

(MC controller communication CAN)

Error code Fault Reason
11006-2 Engine controller communication failure Line east fault ECF fault
11007-2 Monitor controller (information) communication failure 1 (CANO) Line failure Monitoring controller failure
11008-2 Monitor controller (information) communication failure 2 (CAN1) Line east failure Monitoring and control medical failure
11009-2 Monitor controller (monitor) communication failure 1 (CANO) Line east bundle failure Monitoring and excavation controller failure
11010-2 Monitor controller (monitor) communication failure 2 (CAN1) Wiring harness failure Monitoring controller failure

Hitachi ZX470-5G Direct Injection Excavator Error Code

(MC Controller Engine Failure)

Error code Fault Reason
11101-3 Engine control knob sensor circuit high voltage input Voltage: Above 4.75V
11101-4 Engine control knob sensor circuit low voltage input Voltage: Below 0.25V

Hitachi ZX470-5G Direct Injection Excavator Fault Code

(MC Controller Pump Failure)

Error code Fault Reason
11200-3 Pump 1 oil delivery pressure sensor circuit high voltage input Voltage: Above 4.75V
11200-4 Pump 1 oil delivery pressure sensor circuit low-pressure input Voltage: Below 0.25V
11202-3 Pump 2 oil delivery pressure sensor circuit high voltage input Voltage: Above 4.75V
11202-4 Pump 2 oil delivery pressure sensor circuit low-pressure input Voltage: Below 0.25V

Hitachi ZX470-5G Direct Injection Excavator Fault Code

(MC Controller Pilot Failure)

Error code Fault Reason
11301-3 Rotary pilot pressure sensor circuit high-pressure input Voltage: Above 4.75V
11301-4 Rotary pilot pressure sensor circuit low-pressure input Voltage: Below 0.1V
11302-3 Boom hoist pilot pressure sensor circuit high voltage input Voltage: Above 4.75V
11302-4 Boom hoist pilot pressure sensor circuit low voltage input Voltage: Below 0.1V
11303-3 Stick retraction pilot pressure sensor circuit high voltage input Voltage: Above 4.75V
11303-4 Stick retraction pilot pressure sensor circuit high voltage input Voltage: Below 0.1V
11304-3 Travel pilot pressure sensor circuit high voltage input Voltage: Above 4.75V
11304-4 Travel pilot pressure sensor circuit low voltage input Voltage: Below 0.1V
11325-3 Bucket roll-in pilot pressure sensor circuit high voltage input Voltage: Above 4.75V
11325-4 Bucket roll-in pilot pressure sensor circuit low voltage input Voltage: Below 0.1V

Hitachi ZX470-5G Direct Injection Excavator Error Code

(MC Controller Proportional Solenoid Valves)

Error code Fault Reason
11405-3 4-link solenoid valve device (SC)FB high current input 电压:高于4.25V
11405-4 4-link solenoid valve device (SC) FB small current input 电压:低于0.2V
11408-3 4-link solenoid valve device (SF)FB high current input 电流:大于920mA
11408-4 4-link solenoid valve device (SF) FB small current input 电流:小于56mA
11428-3 4-link solenoid valve device (SG)FB high current input 电流:大于920mA
11428-4 4-link solenoid valve device (SG) FB small current input 电流:小于56mA

Hitachi ZX470-5G Direct Injection Excavator Error Code

(Other faults of MC controller)

Error code Fault Reason
111901-3 High voltage input of hydraulic oil temperature sensor circuit Voltage: above 4.25V
11901-4 Low voltage input of hydraulic oil temperature sensor circuit Voltage: Below 0.1V
11940-3 Auxiliary control solenoid valve device (SA) FB large current output Current: more than 920mA
11940-4 Auxiliary control solenoid valve device (SA) FB small current input Current: less than 56mA
11941-3 Auxiliary control solenoid valve device (SC) FB large current input Current: more than 920mA
11941-4 Auxiliary control solenoid valve device (SC) FB small current input Current: less than 56mA
11942-3 Accessory pilot pressure sensor circuit high pressure input (optional) Voltage: above 4.25V
11942-4 Accessory pilot pressure sensor circuit low-pressure input (optional) Voltage: Below 0.1V
11944-3 5-side pilot pressure sensor circuit high voltage input Voltage: above 4.25V
11944-4 5-side pilot pressure sensor circuit low-pressure input Voltage: Below 0.1V
11945-3 4-side pilot pressure sensor circuit high voltage input Voltage: above 4.25V
11945-4 4-side pilot pressure sensor circuit low-pressure input Voltage: Below 0.1V
11948-3 4-link solenoid valve device (SI) FB high current input Current: more than 920mA
11948-4 4-way solenoid valve device (S) FB small current input Current: less than 56mA
11950-3 Pump 2 controls solenoid valve FB high current input Current: more than 920mA
11950-4 Pump 2 controls solenoid valve FB low current input Current: less than 56mA
11951-3 Pump 1 controls solenoid valve FB high current input Current: more than 920mA
11951-4 Pump 1 controls solenoid valve FB small current input Current: less than 56mA
11953-3 2-link solenoid valve device (SI) FB large current input Current: more than 920mA
11953-4 2-link solenoid valve device (SI) FB small current input Current: less than 56mA
11955-3 Pump 2 Displacement Angle Sensor Circuit High Voltage Input Voltage: above 4.25V
11955-4 Pump 2 Displacement Angle Sensor Circuit Low Voltage Input Voltage: Below 0.1V
11956-3 Pump 1 Displacement Angle Sensor Circuit High Voltage Input Voltage: above 4.25V
11956-4 Pump 1 Displacement Angle Sensor Circuit Low Voltage Input Voltage: Below 0.1V
11978-3 Auxiliary 2 analog input circuit high voltage input (optional) Voltage: above 4.25V
11978-4 Auxiliary 2 analog input circuit low voltage input (optional) Voltage: Below 0.1V
11979-3 Auxiliary 1 analog input circuit high voltage input (optional) Voltage: above 4.25V
11979-4 Auxiliary 1 analog input circuit low voltage input (optional) Voltage: Below 0.1V
11980-3 Auxiliary control solenoid valve device (SB) FB large flow input Current: more than 920mA
11980-4 Auxiliary control solenoid valve device (SB) FB small current input Current: less than 56mA
11989-3 2-link solenoid valve device (SC) FB large current input Current: more than 920mA
11989-4 2-link solenoid valve device (SC) FB small current input Current: less than 56mA
11995-3 Stick extends pilot pressure sensor circuit high voltage input Voltage: above 4.25V
11995-4 Stick extends pilot pressure sensor circuit low-pressure input Voltage: Below 0.1V
11997-3 Bucket tip-out pilot pressure sensor circuit high voltage input Voltage: above 4.25V
11997-4 Bucket tip-out pilot pressure sensor circuit low voltage input Voltage: Below 0.1V
11998-3 Boom Down Pilot Pressure Sensor Circuit High Voltage Input Voltage: above 4.25V
11998-4 Boom down pilot pressure sensor circuit low-pressure input Voltage: Below 0.1V
20062-2 Hydraulic oil overheat alarm High temperature of hydraulic oil

Hitachi ZX470-5G Direct Injection Excavator Error Code

(Engine Controller ECF Failure)

Error code Fault Reason
11600-2 EEPROM: Abnormal ECF failure
11601-2 RAM guide ECF failure
11602-2 A/D conversion abnormality ECF failure
11603-3 Abnormal sensor voltage ECF fault sensor fault Line east fault
11604-2 CAN communication abnormality ECF fault CAN harness fault
11605-2 Abnormal engine speed (overspeeding) Engine speed exceeds 4000 rpm
11606-3 EC angle sensor high voltage abnormality Voltage: higher than 4.78V
11606-4 EC angle sensor low voltage abnormality Voltage: Below 0.22V
11607-2 Send target engine speed from MC Wiring harness failure

Hitachi ZX470-5G Direct Injection Excavator Error Code

(Display Monitor)

Error code Fault Reason
13002-2 ECF communication error Monitor controller failure CAN 0 line east failure
13003-2 MC communication error 1 Monitor controller failure CAN 0 line east failure
13004-2 MC communication error 2 Monitor controller failure CAN 1 harness failure
13005-2 Monitor Controller (Message) Communication Error 1 Monitor controller failure CAN 0 line east failure
13006-2 Monitor Controller (Message) Communication Error 2 Monitor controller failure CAN 1 harness failure
13007-2 Wiper/light controller communication error Monitor controller failure CAN 1 harness failure
20113-2 System failure alarm CAN communication bus failure

Hitachi ZX470-5G Direct Injection Excavator Error Code

(Display Monitor)

Error code Fault Reason
14001-2 Flash memory: read/write error Monitor controller memory
14002-2 External RAM: read/write error Monitor controller memory
14003-2 EEPROM abnormality Monitor controller memory
14006-2 Communication terminal: communication error Communication error with communication equipment
14008-2 Internal RAM abnormality Monitor controller memory exception
14021-2 Communication terminal security error Security failure of mobile communication equipment
14022-2 SIM card error Abnormal SIM card in mobile communication equipment
14023-2 Security Error Communication error with MC
13303-2 Thermistor temperature (monitor internal temperature) is abnormal Thermistor temperature: 85℃ or above
13304-2 Regulator input H level abnormality Alternator power generation voltage: 33.5V or above
13310-3 Coolant temperature sensor short circuit 500 or less for 60 seconds
13311-3 Fuel sensor open circuit 1.14±1Ω or less for 60 seconds
13311-4 Fuel sensor short circuit 500+200 or less for 60 seconds
20100-2 overheat alarm Coolant temperature is high when the engine is running
20101-2 Generator warning alarm Generator system failure
20102-2 Oil pressure alarm Oil pressure drops
20105-2 Hydraulic oil filter clogging alarm Hydraulic oil filter clogged wiring harness open circuit
20106-2 Air filter clogged alarm air filter clogged
20109-2 Pilot control throttle lever alarm Pilot cut-off switch failure
20114-2 Overheating alarm The coolant temperature is high within 10 seconds after the engine is started.

Hitachi ZX470-5G Direct Injection Excavator Error Code

(Air Conditioner Controller)

Error code Fault Reason
11 Air circulation sensor open circuit Voltage: over 4.95V
12 Air circulation sensor short circuit Voltage: Below 0.3V
13 Fresh air sensor open circuit Voltage: More than 4.88V
14 Fresh air sensor short circuit Voltage: less than 0.096y
18 Solar radiation sensor short circuit Voltage: over 5.04V
21 Evaporator sensor open circuit Voltage: over 4.79V
22 Evaporator sensor short circuit Voltage: less than 0.096V
43 Abnormal vent baffle Short circuit: Voltage: 0V Open circuit: Voltage: higher than 5V
44 Mix air damper abnormality Short circuit: Voltage: lower than 0.2V Open circuit: Voltage: higher than 4.8V
51 Abnormal high/low refrigerant pressure Voltage: 0V
91 CAN communication failure CAN1 harness failure between monitor controller and air conditioning controller
92 CAN bus new line failure Air conditioning controller failure CAN1 wiring harness failure

Hitachi ZX470-5G Direct Injection Excavator Error Code

(Air Conditioner Controller)

Error code Fault Reason
14100-2 14100-2 communication terminal: EEPROM abnormality The memory (optional) of the satellite communication terminal is abnormal.
14101-2 14101-2 Communication terminal: IB/OB queue abnormality The memory (optional) of the satellite communication terminal is abnormal.
14102-2 14102-2 Communication terminal: Local loopback exception Anomaly detected during communication test with satellite
14103-2 14103-2 Communication Terminal: No satellite found Can’t capture satellites
14104-2 14104-2 Communication terminal: Remote loopback failure 1 Anomalies detected in communications tests with satellites and base stations
14105-2 14105-2 Communication terminal: Remote loopback failure 2 Anomalies detected in communications tests with satellites and base stations
14106-2 14106-2 Communication terminal: Transmission/reception data mismatch Mismatch with satellite’s transmit/receive data
14107-2 14107-2 Communication terminal: GSM module abnormality Mobile communication equipment abnormality

If you want to know more about Hitachi excavator error codes and troubleshooting, just feel free to contact us at sales@aprilparts.com. We’re glad to help.

Related Articles:

0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply

Your email address will not be published. Required fields are marked *