To make it easier for you to understand these error codes, deal with the faulty machine promptly, replace appropriate parts, and ensure the normal operation of the excavator, Aprilparts will introduce to you the error codes displayed on the SK200-10 instrument monitoring panel in this blog. Hope this helps.

Kobelco SK200-10 Excavator Engine Error Code

P0217, Overheating

P2229, Barometric pressure sensor failure (high)

P0193, Common rail pressure sensor failure (high)

P0237, Suction pressure sensor failure (low)

PO117, Water temperature sensor failure (low)

P0182, Fuel temperature sensor failure (low)

P2120, Dual throttle sensor failure

P2123, Throttle sensor 1 fault (high)

P2128, Throttle sensor 2 fault (high)

P0335, Main speed sensor failure, dual rotation sensor failure

P0340, Auxiliary speed sensor failure

P0629, SCV valve (+) VB short circuit

P0088, Common rail abnormal high pressure (stage 1)

P2635, Fuel supply pump abnormal high pressure history/Fuel supply pump solenoid valve stuck

P1214, Injector common 2 fault (short circuit to ground)

P1215, Injector common 2 fault (VB short circuit)

P1215, Injector common 2 fault (on)

P0202, Injector 2 disconnected

P0204, Injector 4 disconnected

P0266, Cylinder to Cylinder Correction Error #2

P0272, Cylinder to Cylinder Correction Error #4

P0490, EGR linear solenoid 1 fault (VB short circuit)

P0405, EGR lifter sensor 1 fault (low)

P2228, Barometric pressure sensor failure (low)

P0192, Common rail pressure sensor failure (low)

P0191, Common rail pressure sensor failure

P0108, Suction pressure sensor failure (high)

P0118, Water temperature sensor failure (high)

P0183, Fuel Temperature Sensor Failure (High)

P2122, Throttle sensor 1 fault (low)

P2127, Throttle sensor 2 fault (low)

P1133, Service Throttle Sensor (High)

P0336, Main speed sensor pulse abnormality

P0341, Secondary speed sensor pulse abnormality

P0628, SCV valve other abnormality

P0088, Common rail abnormal high pressure (stage 2)

P1211, Injector common 1 fault (short circuit to ground)

P1212, Injector common 1 fault (VB short circuit)

P1212, Injector common 1 fault (on)

P0201, Injector 1 disconnected

P0203, Injector 3 disconnected

P0263, Cylinder to Cylinder Correction Error #1

P0269, Cylinder to Cylinder Correction Error #3

P0489, EGR linear electromagnetic 1 fault (broken wire and short circuit to ground)

P0404, EGR valve stuck 1

P0406, EGR lifter sensor 1 fault (high)

P0234, Turbocharger overload

P0200, ECU charging circuit failure (high)

P0606, CPU failure (faulty hard disk detected)

P1601, QR code failure

P0686, Main relay failure

P0617, Starter switch failure

U110A, Communication interruption (electromechanical controller TSC1) P0611,

P0611, ECU charging circuit failure (low)

P0605, Flash memory error

P0607, CPU monitoring IC abnormality

P0540, Preheating device failure

P0219, Engine overrun

P1530, Engine stop switch malfunction

Kobelco SK200-10 Excavator Electromechanical Hydraulic Controller Error Codes

A015, the electromechanical storage value of engine adjustment data is incorrect.

A035, the unloading adjustment data electromechanical storage value is incorrect

A055, the electromechanical storage value of the forearm retraction adjustment data is incorrect.

A075, the electromechanical storage value of the right offset adjustment data is incorrect

A095, the electromechanical storage value of the middle boom lifting adjustment data is incorrect.

A115, the electromechanical storage value of the adjustment data before and after tilt measurement is incorrect.

A215, the adjustment data selection electromechanical storage value is incorrect

A235, the electromechanical storage value of working hour adjustment data 1 is incorrect

A255, the electromechanical storage value of the proportional valve adjustment data is incorrect.

B012, boom rising low pressure sensor output abnormality

B014, boom rising low voltage sensor power supply short circuit

B022, boom lower pressure sensor output abnormality

B024, boom lower voltage sensor power supply short circuit

B032, The output of the low pressure sensor of the forearm is abnormal

B034, low-voltage sensor power supply of the forearm is short-circuited

B042, arm recovery low pressure sensor output abnormality

B044, arm recovery low voltage sensor power supply short circuit

B052, bucket recovery low pressure sensor output abnormality

B054, Bucket recycling low voltage sensor power supply short circuit

B062, Bucket lifting low pressure sensor output abnormality

A025, the electromechanical storage value of torque adjustment data is incorrect

A045, the electromechanical storage value of the boom lifting adjustment data is incorrect.

A065, the electromechanical storage value of the forearm extension adjustment data is incorrect.

A085, the left offset adjustment data electromechanical storage value is incorrect

A105, the electromechanical storage value of the middle boom lowering adjustment data is incorrect.

A125, the electromechanical storage value of the tilt measurement left and right adjustment data is incorrect.

A225, the electromechanical storage value of adjustment data sector 2 is incorrect.

A245, the electromechanical storage value of working hour adjustment data 2 is incorrect

B010, the boom rising low pressure sensor is larger than the normal range

B013, boom rising low pressure sensor disconnected

B020, the boom down pressure sensor is larger than the normal range

B023, boom lower pressure sensor disconnected

B030, the low pressure sensor of the forearm is larger than the normal range

B033, low-voltage sensor of the forearm is disconnected

B040, the low pressure sensor of arm recovery is larger than the normal range

B043, arm recovery low pressure sensor disconnected

B050, bucket recovery low pressure sensor is larger than normal range

B053, bucket recovery low pressure sensor disconnected

B060, the low pressure sensor of the bucket is larger than the normal range

B063, Bucket lifting low pressure sensor disconnected

B064, Bucket lifting low voltage sensor power supply short circuit

B072, Rotating low pressure sensor output abnormality

B074, Rotary low voltage sensor power supply short circuit

B092, Right walking low pressure sensor output abnormality

B094, right running low voltage sensor power supply short circuit

B102, left walking low pressure sensor output abnormality

B104, left walking low voltage sensor power supply short circuit

B112, detects abnormal output of low pressure sensor at selected position

B114, detects the short circuit of the low voltage sensor power supply in the selected position

B122, abnormal output of low pressure sensor when clamp arm moves up and down

B124, clamp arm moves up and down low voltage sensor power supply short circuit

B132, left bias low voltage sensor output abnormality

B134, left bias low voltage sensor power supply short circuit

B142, Right bias low voltage sensor output abnormality

B144, right bias low voltage sensor power supply short circuit

B152, abnormal output of right rear walking low pressure sensor

B154, right rear running low voltage sensor power supply short circuit

B162, P1 side optional low pressure sensor output abnormality

B164, P1 side optional low voltage sensor power supply short circuit

B172, P2 side optional low pressure sensor output abnormality

B174, P2 side optional low voltage sensor power supply short circuit

B182, Bulldozer rising low pressure sensor output abnormality

B184, Bulldozer rising low voltage sensor power supply short circuit

B192, The output of the pressure sensor when lowering the bulldozer is abnormal.

B194, Bulldozer lower voltage sensor power supply short circuit

B202, abnormal output of low pressure sensor on the left rear while walking

B204, walking left rear low voltage sensor power supply short circuit

C012, P1 pump high pressure sensor output abnormality

C014, P1 pump high voltage sensor power supply short circuit

C022, P2 pump high pressure sensor output abnormality

C024, P2 pump high voltage sensor power supply short circuit

C032, abnormal output of high pressure sensor in big arm chamber

C034, short circuit in the power supply of the high-voltage sensor in the big arm and cavity

B070, rotating low pressure sensor is larger than normal range

B073, Rotary low pressure sensor disconnected

B090, right walking low pressure sensor is larger than normal range

B093, right running low voltage sensor disconnected

B100, left walking low pressure sensor is larger than normal range

B103, left walking low voltage sensor disconnected

B110, the low pressure sensor in the selected position is greater than the normal range.

B113, detect selected position low pressure sensor disconnection

B120, the clamp arm moves up and down the low pressure sensor beyond the normal range.

B123, the low-voltage sensor of the clamp arm moving up and down is disconnected

B130, left bias low pressure sensor is larger than normal range

B133, left bias low voltage sensor disconnected

B140, right bias low pressure sensor is larger than normal range

B143, right bias low voltage sensor disconnected

B150, the right rear walking low pressure sensor is larger than the normal range

B153, right rear traveling low voltage sensor disconnected

B160, the optional low pressure sensor on the P1 side is larger than the normal range

B163, the optional low-voltage sensor on the P1 side is disconnected

B170, the optional low pressure sensor on the P2 side is larger than the normal range

B173, the optional low-voltage sensor on the P2 side is disconnected

B180, bulldozer rising low pressure sensor is larger than normal range

B183, bulldozer rising low pressure sensor disconnected

B190, the bulldozer lower pressure sensor is larger than the normal range

B193, bulldozer lower pressure sensor disconnected

B200, walking left rear low pressure sensor is larger than normal range

B203, walking left rear low voltage sensor disconnected

C010, P1 pump high pressure sensor is larger than normal range

C013, P1 pump high pressure sensor disconnected

C020, P2 pump high pressure sensor is larger than normal range

C023, P2 pump high pressure sensor disconnected

C030, the high pressure sensor of the big arm and large cavity is larger than the normal range

C033, the high-pressure sensor of the big arm is disconnected

C040, the high pressure sensor in the large buttocks and small cavity is larger than the normal range

C042, abnormal output of high-pressure sensor in small cavity of big arm

C044, power supply of high-voltage sensor in big arm and small cavity is short-circuited

C052, Overload valve high pressure sensor output abnormality

C054, overload valve high pressure sensor power supply short circuit

C062, reserved 1 high voltage sensor output abnormality

C064, reserved 1 high voltage sensor power supply short circuit

C072, reserved 2 high voltage sensor output abnormality

C074, reserved 2 high voltage sensor power supply short circuit

D013, P1 unloading proportional valve disconnected

D023, P2 unloading proportional valve disconnected

D033, traveling linear proportional valve disconnected

D043, boom rising proportional valve disconnected

D053, boom lowering proportional valve disconnected

D063, arm recovery 2-speed proportional valve disconnected

D073, arm lift proportional valve disconnected

D083, arm recovery proportional valve disconnected

D093, right bias proportional valve disconnected

D103, left bias proportional valve disconnected

D113, P1 traveling independent proportional valve disconnected

D123, P2 traveling independent proportional valve disconnected

D133, arm variable regeneration proportional valve disconnected

D143, fan drive proportional valve disconnected

D153, Unicom proportional valve disconnected

D163, ready 1 proportional valve disconnected

D173, boom regeneration proportional valve disconnected

D183, big arm M/0 proportional valve disconnected

E013, P1 pump proportional valve disconnected

E023, P2 pump proportional valve disconnected

E033, select relief 1 proportional valve disconnected

E043, select relief 2 proportional valve disconnected

F013, working device booster solenoid valve transistor ON fault/disconnection

F021, Rotary parking solenoid valve transistor OFF fault/ground short circuit

F031, travel 1,2 speed solenoid valve transistor OFF fault/ground short circuit

C043, big arm small cavity high pressure sensor disconnected

C050, the high pressure sensor of the overload valve is greater than the normal range

C053, overload valve high pressure sensor disconnected

C060, reserved 1 high pressure sensor is larger than the normal range

C063, reserved 1 high voltage sensor disconnected

C070, reserved 2 high-voltage sensors are larger than the normal range

C073, reserved 2 high voltage sensors are disconnected

D012, P1 unloading proportional valve transistor ON fault

D022, P2 unloading proportional valve transistor ON fault

D032, travel linear proportional valve transistor ON fault

D042, boom rising proportional valve transistor ON fault

D052, boom lowering proportional valve transistor ON fault

D062, arm recovery 2-speed proportional valve transistor ON failure

D072, arm lift proportional valve transistor ON fault

D082, arm recovery proportional valve transistor ON failure

D092, right bias proportional valve transistor ON fault

D102, left bias proportional valve transistor ON fault

D112, P1 walking independent proportional valve transistor 0N fault

D122, P2 walking independent proportional valve transistor 0N fault

D132, arm variable regeneration proportional valve transistor ON fault

D142, fan drive proportional valve transistor ON fault

D152, China Unicom proportional valve transistor ON fault

D162, Reserve 1 proportional valve transistor ON fault

D172, big arm regeneration proportional valve transistor 0 fault

D182, big arm M/O proportional valve transistor ON fault

E012, P1 pump proportional valve transistor 0N failure

E022, P2 pump proportional valve transistor 0N failure

E032, Select overflow 1 transistor ON fault

E042, Selected overflow 2 transistor ON fault

F011, working device booster solenoid valve transistor 0FF fault/short circuit to ground

F023, Rotary parking solenoid valve transistor ON fault/disconnection

F033, Travel 1.2 speed solenoid valve transistor 0N fault/disconnection

F041, optional solenoid valve transistor 0FF fault/short circuit to ground

F051, fan pump solenoid valve transistor OFF fault/short circuit to ground

F061, Reserve 1 solenoid valve transistor 0FF fault/short circuit to ground

F071, Big arm M/cut-off solenoid valve transistor OFF fault/ground short circuit

G033, the speed sensor directly input by the electromechanical controller is disconnected abnormally

G043, electromechanical controller input speed and engine receiving data disconnection

H013, Throttle potentiometer disconnected

H021, boom angle potentiometer short circuit to ground

H024, arm angle potentiometer power supply short circuit

H033, forearm angle potentiometer disconnected

H041, Offset angle potentiometer short circuit to ground

H044, bias angle potentiometer power supply short circuit

H053, mid-arm angle potentiometer disconnected

H061, left and right tilt angle potentiometer short circuit to ground

H064, left and right tilt angle potentiometer power supply short circuit

H073, front and rear tilt angle potentiometer disconnected

H081, water temperature sensor potentiometer short circuit to ground

H084, water temperature sensor potentiometer power supply short circuit

H093, Diesel sensor potentiometer disconnected

H101, hydraulic oil temperature sensor potentiometer short circuit to ground

H104, hydraulic oil temperature sensor potentiometer power supply short circuit

H113, Hydraulic oil clogged sensor potentiometer disconnected

H121, Rotary speed potentiometer short circuit to ground

H124, rotation speed potentiometer power supply short circuit

I113, CAN communication 1 timeout

I123, CAN communication 1 timeout

I213, CAN communication 2 timeout

I223, CAN communication 2 timeout

I313, LCD communication reception timeout

I323, LCD communication sending timeout

I413, expansion controller communication error

R014, wiper arc prevention relay power supply short circuit

F043, optional solenoid valve transistor ON fault/disconnection

F053, Fan pump solenoid valve transistor ON fault/disconnection

F063, Reserve 1 solenoid valve transistor ON fault/disconnection

F073, large tube M/cut-off solenoid valve transistor ON fault/disconnection

G032, the speed sensor directly input by the electromechanical controller exceeds the limit.

G042, the input speed of the electromechanical controller and the data received by the engine exceed the limit

H011, Throttle potentiometer short circuit to ground

H014, Throttle potentiometer power supply short circuit

H023, big arm angle potentiometer disconnected

H031, arm angle potentiometer short circuit to ground

H034, arm angle potentiometer power supply short circuit

H043, Bias angle potentiometer disconnected

H051, mid-arm angle potentiometer short circuit to ground

H054, mid-arm angle potentiometer power supply short circuit

H063, left and right tilt angle potentiometer disconnected

H071, front and rear tilt angle potentiometer short circuit to ground

H074, front and rear tilt angle potentiometer power supply short circuit

H083, water temperature sensor potentiometer disconnected

H091, diesel sensor potentiometer short circuit to ground

H094, Diesel sensor potentiometer power supply short circuit

H103, hydraulic oil temperature sensor potentiometer disconnected

H111, hydraulic oil clogged sensor potentiometer short circuit to ground

H114, hydraulic oil clogged sensor potentiometer power supply short circuit

H123, Rotation speed potentiometer disconnected

I111, CAN communication 1 error

I121, CAN communication 1 error

I211, CAN communication 2 error

I221, CAN communication 2 error

I311, LCD communication reception error

I321, LCD communication sending error

I411, expansion controller communication error

K014, battery relay node sticking

R024, wiper forward relay power supply short circuit

R034, Wiper reverse relay power supply short circuit

R054, Bucket limit relay power supply short circuit

R144, rotating and flashing left relay power supply short circuit

R164, automatic total speed stop AIS relay 2 power supply short circuit

R184, safety locking relay power supply short circuit

Z010, abnormal common rail pressure value

Z030, pump flow increase compensation value is abnormal

R044, sprinkler motor relay power supply short circuit

R134, rotating and flashing right relay power supply short circuit

R154, walking alarm relay power supply short circuit

R174, engine stop relay power supply short circuit

R214, safety relay power supply short circuit

Z020, abnormal fuel type identification value

Z040, hydraulic oil clogging alarm value is abnormal

If you want to know more about Kobelco excavator error codes and troubleshooting, just feel free to contact us at sales@aprilparts.com. We’re glad to help.

Related Articles:

V0511-24103 Rear Track Idler
16030-51013 Fuel Injection Pump
Z482-M Engine Overhaul Rebuild Kit
Z600 Engine Overhaul Rebuild Kit
ZB600 engine rebuild kit
ZH600 engine rebuild kit
0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply

Your email address will not be published. Required fields are marked *