Kobelco SK200-10 Excavator Engine & Hydraulic Controller Error Code
If a Kobelco SK200-10 excavator malfunctions, an error code will be displayed on the monitoring instrument cluster panel. If the meaning of these error codes is not understood, the machine will operate seriously abnormally.
To make it easier for you to understand these error codes, deal with the faulty machine promptly, replace appropriate parts, and ensure the normal operation of the excavator, Aprilparts will introduce to you the error codes displayed on the SK200-10 instrument monitoring panel in this blog. Hope this helps.
Kobelco SK200-10 Excavator Engine Error Code
P0217, Overheating
P2229, Barometric pressure sensor failure (high)
P0193, Common rail pressure sensor failure (high)
P0237, Suction pressure sensor failure (low)
PO117, Water temperature sensor failure (low)
P0182, Fuel temperature sensor failure (low)
P2120, Dual throttle sensor failure
P2123, Throttle sensor 1 fault (high)
P2128, Throttle sensor 2 fault (high)
P0335, Main speed sensor failure, dual rotation sensor failure
P0340, Auxiliary speed sensor failure
P0629, SCV valve (+) VB short circuit
P0088, Common rail abnormal high pressure (stage 1)
P2635, Fuel supply pump abnormal high pressure history/Fuel supply pump solenoid valve stuck
P1214, Injector common 2 fault (short circuit to ground)
P1215, Injector common 2 fault (VB short circuit)
P1215, Injector common 2 fault (on)
P0202, Injector 2 disconnected
P0204, Injector 4 disconnected
P0266, Cylinder to Cylinder Correction Error #2
P0272, Cylinder to Cylinder Correction Error #4
P0490, EGR linear solenoid 1 fault (VB short circuit)
P0405, EGR lifter sensor 1 fault (low)
P2228, Barometric pressure sensor failure (low)
P0192, Common rail pressure sensor failure (low)
P0191, Common rail pressure sensor failure
P0108, Suction pressure sensor failure (high)
P0118, Water temperature sensor failure (high)
P0183, Fuel Temperature Sensor Failure (High)
P2122, Throttle sensor 1 fault (low)
P2127, Throttle sensor 2 fault (low)
P1133, Service Throttle Sensor (High)
P0336, Main speed sensor pulse abnormality
P0341, Secondary speed sensor pulse abnormality
P0628, SCV valve other abnormality
P0088, Common rail abnormal high pressure (stage 2)
P1211, Injector common 1 fault (short circuit to ground)
P1212, Injector common 1 fault (VB short circuit)
P1212, Injector common 1 fault (on)
P0201, Injector 1 disconnected
P0203, Injector 3 disconnected
P0263, Cylinder to Cylinder Correction Error #1
P0269, Cylinder to Cylinder Correction Error #3
P0489, EGR linear electromagnetic 1 fault (broken wire and short circuit to ground)
P0404, EGR valve stuck 1
P0406, EGR lifter sensor 1 fault (high)
P0234, Turbocharger overload
P0200, ECU charging circuit failure (high)
P0606, CPU failure (faulty hard disk detected)
P1601, QR code failure
P0686, Main relay failure
P0617, Starter switch failure
U110A, Communication interruption (electromechanical controller TSC1) P0611,
P0611, ECU charging circuit failure (low)
P0605, Flash memory error
P0607, CPU monitoring IC abnormality
P0540, Preheating device failure
P0219, Engine overrun
P1530, Engine stop switch malfunction
Kobelco SK200-10 Excavator Electromechanical Hydraulic Controller Error Codes
A015, the electromechanical storage value of engine adjustment data is incorrect.
A035, the unloading adjustment data electromechanical storage value is incorrect
A055, the electromechanical storage value of the forearm retraction adjustment data is incorrect.
A075, the electromechanical storage value of the right offset adjustment data is incorrect
A095, the electromechanical storage value of the middle boom lifting adjustment data is incorrect.
A115, the electromechanical storage value of the adjustment data before and after tilt measurement is incorrect.
A215, the adjustment data selection electromechanical storage value is incorrect
A235, the electromechanical storage value of working hour adjustment data 1 is incorrect
A255, the electromechanical storage value of the proportional valve adjustment data is incorrect.
B012, boom rising low pressure sensor output abnormality
B014, boom rising low voltage sensor power supply short circuit
B022, boom lower pressure sensor output abnormality
B024, boom lower voltage sensor power supply short circuit
B032, The output of the low pressure sensor of the forearm is abnormal
B034, low-voltage sensor power supply of the forearm is short-circuited
B042, arm recovery low pressure sensor output abnormality
B044, arm recovery low voltage sensor power supply short circuit
B052, bucket recovery low pressure sensor output abnormality
B054, Bucket recycling low voltage sensor power supply short circuit
B062, Bucket lifting low pressure sensor output abnormality
A025, the electromechanical storage value of torque adjustment data is incorrect
A045, the electromechanical storage value of the boom lifting adjustment data is incorrect.
A065, the electromechanical storage value of the forearm extension adjustment data is incorrect.
A085, the left offset adjustment data electromechanical storage value is incorrect
A105, the electromechanical storage value of the middle boom lowering adjustment data is incorrect.
A125, the electromechanical storage value of the tilt measurement left and right adjustment data is incorrect.
A225, the electromechanical storage value of adjustment data sector 2 is incorrect.
A245, the electromechanical storage value of working hour adjustment data 2 is incorrect
B010, the boom rising low pressure sensor is larger than the normal range
B013, boom rising low pressure sensor disconnected
B020, the boom down pressure sensor is larger than the normal range
B023, boom lower pressure sensor disconnected
B030, the low pressure sensor of the forearm is larger than the normal range
B033, low-voltage sensor of the forearm is disconnected
B040, the low pressure sensor of arm recovery is larger than the normal range
B043, arm recovery low pressure sensor disconnected
B050, bucket recovery low pressure sensor is larger than normal range
B053, bucket recovery low pressure sensor disconnected
B060, the low pressure sensor of the bucket is larger than the normal range
B063, Bucket lifting low pressure sensor disconnected
B064, Bucket lifting low voltage sensor power supply short circuit
B072, Rotating low pressure sensor output abnormality
B074, Rotary low voltage sensor power supply short circuit
B092, Right walking low pressure sensor output abnormality
B094, right running low voltage sensor power supply short circuit
B102, left walking low pressure sensor output abnormality
B104, left walking low voltage sensor power supply short circuit
B112, detects abnormal output of low pressure sensor at selected position
B114, detects the short circuit of the low voltage sensor power supply in the selected position
B122, abnormal output of low pressure sensor when clamp arm moves up and down
B124, clamp arm moves up and down low voltage sensor power supply short circuit
B132, left bias low voltage sensor output abnormality
B134, left bias low voltage sensor power supply short circuit
B142, Right bias low voltage sensor output abnormality
B144, right bias low voltage sensor power supply short circuit
B152, abnormal output of right rear walking low pressure sensor
B154, right rear running low voltage sensor power supply short circuit
B162, P1 side optional low pressure sensor output abnormality
B164, P1 side optional low voltage sensor power supply short circuit
B172, P2 side optional low pressure sensor output abnormality
B174, P2 side optional low voltage sensor power supply short circuit
B182, Bulldozer rising low pressure sensor output abnormality
B184, Bulldozer rising low voltage sensor power supply short circuit
B192, The output of the pressure sensor when lowering the bulldozer is abnormal.
B194, Bulldozer lower voltage sensor power supply short circuit
B202, abnormal output of low pressure sensor on the left rear while walking
B204, walking left rear low voltage sensor power supply short circuit
C012, P1 pump high pressure sensor output abnormality
C014, P1 pump high voltage sensor power supply short circuit
C022, P2 pump high pressure sensor output abnormality
C024, P2 pump high voltage sensor power supply short circuit
C032, abnormal output of high pressure sensor in big arm chamber
C034, short circuit in the power supply of the high-voltage sensor in the big arm and cavity
B070, rotating low pressure sensor is larger than normal range
B073, Rotary low pressure sensor disconnected
B090, right walking low pressure sensor is larger than normal range
B093, right running low voltage sensor disconnected
B100, left walking low pressure sensor is larger than normal range
B103, left walking low voltage sensor disconnected
B110, the low pressure sensor in the selected position is greater than the normal range.
B113, detect selected position low pressure sensor disconnection
B120, the clamp arm moves up and down the low pressure sensor beyond the normal range.
B123, the low-voltage sensor of the clamp arm moving up and down is disconnected
B130, left bias low pressure sensor is larger than normal range
B133, left bias low voltage sensor disconnected
B140, right bias low pressure sensor is larger than normal range
B143, right bias low voltage sensor disconnected
B150, the right rear walking low pressure sensor is larger than the normal range
B153, right rear traveling low voltage sensor disconnected
B160, the optional low pressure sensor on the P1 side is larger than the normal range
B163, the optional low-voltage sensor on the P1 side is disconnected
B170, the optional low pressure sensor on the P2 side is larger than the normal range
B173, the optional low-voltage sensor on the P2 side is disconnected
B180, bulldozer rising low pressure sensor is larger than normal range
B183, bulldozer rising low pressure sensor disconnected
B190, the bulldozer lower pressure sensor is larger than the normal range
B193, bulldozer lower pressure sensor disconnected
B200, walking left rear low pressure sensor is larger than normal range
B203, walking left rear low voltage sensor disconnected
C010, P1 pump high pressure sensor is larger than normal range
C013, P1 pump high pressure sensor disconnected
C020, P2 pump high pressure sensor is larger than normal range
C023, P2 pump high pressure sensor disconnected
C030, the high pressure sensor of the big arm and large cavity is larger than the normal range
C033, the high-pressure sensor of the big arm is disconnected
C040, the high pressure sensor in the large buttocks and small cavity is larger than the normal range
C042, abnormal output of high-pressure sensor in small cavity of big arm
C044, power supply of high-voltage sensor in big arm and small cavity is short-circuited
C052, Overload valve high pressure sensor output abnormality
C054, overload valve high pressure sensor power supply short circuit
C062, reserved 1 high voltage sensor output abnormality
C064, reserved 1 high voltage sensor power supply short circuit
C072, reserved 2 high voltage sensor output abnormality
C074, reserved 2 high voltage sensor power supply short circuit
D013, P1 unloading proportional valve disconnected
D023, P2 unloading proportional valve disconnected
D033, traveling linear proportional valve disconnected
D043, boom rising proportional valve disconnected
D053, boom lowering proportional valve disconnected
D063, arm recovery 2-speed proportional valve disconnected
D073, arm lift proportional valve disconnected
D083, arm recovery proportional valve disconnected
D093, right bias proportional valve disconnected
D103, left bias proportional valve disconnected
D113, P1 traveling independent proportional valve disconnected
D123, P2 traveling independent proportional valve disconnected
D133, arm variable regeneration proportional valve disconnected
D143, fan drive proportional valve disconnected
D153, Unicom proportional valve disconnected
D163, ready 1 proportional valve disconnected
D173, boom regeneration proportional valve disconnected
D183, big arm M/0 proportional valve disconnected
E013, P1 pump proportional valve disconnected
E023, P2 pump proportional valve disconnected
E033, select relief 1 proportional valve disconnected
E043, select relief 2 proportional valve disconnected
F013, working device booster solenoid valve transistor ON fault/disconnection
F021, Rotary parking solenoid valve transistor OFF fault/ground short circuit
F031, travel 1,2 speed solenoid valve transistor OFF fault/ground short circuit
C043, big arm small cavity high pressure sensor disconnected
C050, the high pressure sensor of the overload valve is greater than the normal range
C053, overload valve high pressure sensor disconnected
C060, reserved 1 high pressure sensor is larger than the normal range
C063, reserved 1 high voltage sensor disconnected
C070, reserved 2 high-voltage sensors are larger than the normal range
C073, reserved 2 high voltage sensors are disconnected
D012, P1 unloading proportional valve transistor ON fault
D022, P2 unloading proportional valve transistor ON fault
D032, travel linear proportional valve transistor ON fault
D042, boom rising proportional valve transistor ON fault
D052, boom lowering proportional valve transistor ON fault
D062, arm recovery 2-speed proportional valve transistor ON failure
D072, arm lift proportional valve transistor ON fault
D082, arm recovery proportional valve transistor ON failure
D092, right bias proportional valve transistor ON fault
D102, left bias proportional valve transistor ON fault
D112, P1 walking independent proportional valve transistor 0N fault
D122, P2 walking independent proportional valve transistor 0N fault
D132, arm variable regeneration proportional valve transistor ON fault
D142, fan drive proportional valve transistor ON fault
D152, China Unicom proportional valve transistor ON fault
D162, Reserve 1 proportional valve transistor ON fault
D172, big arm regeneration proportional valve transistor 0 fault
D182, big arm M/O proportional valve transistor ON fault
E012, P1 pump proportional valve transistor 0N failure
E022, P2 pump proportional valve transistor 0N failure
E032, Select overflow 1 transistor ON fault
E042, Selected overflow 2 transistor ON fault
F011, working device booster solenoid valve transistor 0FF fault/short circuit to ground
F023, Rotary parking solenoid valve transistor ON fault/disconnection
F033, Travel 1.2 speed solenoid valve transistor 0N fault/disconnection
F041, optional solenoid valve transistor 0FF fault/short circuit to ground
F051, fan pump solenoid valve transistor OFF fault/short circuit to ground
F061, Reserve 1 solenoid valve transistor 0FF fault/short circuit to ground
F071, Big arm M/cut-off solenoid valve transistor OFF fault/ground short circuit
G033, the speed sensor directly input by the electromechanical controller is disconnected abnormally
G043, electromechanical controller input speed and engine receiving data disconnection
H013, Throttle potentiometer disconnected
H021, boom angle potentiometer short circuit to ground
H024, arm angle potentiometer power supply short circuit
H033, forearm angle potentiometer disconnected
H041, Offset angle potentiometer short circuit to ground
H044, bias angle potentiometer power supply short circuit
H053, mid-arm angle potentiometer disconnected
H061, left and right tilt angle potentiometer short circuit to ground
H064, left and right tilt angle potentiometer power supply short circuit
H073, front and rear tilt angle potentiometer disconnected
H081, water temperature sensor potentiometer short circuit to ground
H084, water temperature sensor potentiometer power supply short circuit
H093, Diesel sensor potentiometer disconnected
H101, hydraulic oil temperature sensor potentiometer short circuit to ground
H104, hydraulic oil temperature sensor potentiometer power supply short circuit
H113, Hydraulic oil clogged sensor potentiometer disconnected
H121, Rotary speed potentiometer short circuit to ground
H124, rotation speed potentiometer power supply short circuit
I113, CAN communication 1 timeout
I123, CAN communication 1 timeout
I213, CAN communication 2 timeout
I223, CAN communication 2 timeout
I313, LCD communication reception timeout
I323, LCD communication sending timeout
I413, expansion controller communication error
R014, wiper arc prevention relay power supply short circuit
F043, optional solenoid valve transistor ON fault/disconnection
F053, Fan pump solenoid valve transistor ON fault/disconnection
F063, Reserve 1 solenoid valve transistor ON fault/disconnection
F073, large tube M/cut-off solenoid valve transistor ON fault/disconnection
G032, the speed sensor directly input by the electromechanical controller exceeds the limit.
G042, the input speed of the electromechanical controller and the data received by the engine exceed the limit
H011, Throttle potentiometer short circuit to ground
H014, Throttle potentiometer power supply short circuit
H023, big arm angle potentiometer disconnected
H031, arm angle potentiometer short circuit to ground
H034, arm angle potentiometer power supply short circuit
H043, Bias angle potentiometer disconnected
H051, mid-arm angle potentiometer short circuit to ground
H054, mid-arm angle potentiometer power supply short circuit
H063, left and right tilt angle potentiometer disconnected
H071, front and rear tilt angle potentiometer short circuit to ground
H074, front and rear tilt angle potentiometer power supply short circuit
H083, water temperature sensor potentiometer disconnected
H091, diesel sensor potentiometer short circuit to ground
H094, Diesel sensor potentiometer power supply short circuit
H103, hydraulic oil temperature sensor potentiometer disconnected
H111, hydraulic oil clogged sensor potentiometer short circuit to ground
H114, hydraulic oil clogged sensor potentiometer power supply short circuit
H123, Rotation speed potentiometer disconnected
I111, CAN communication 1 error
I121, CAN communication 1 error
I211, CAN communication 2 error
I221, CAN communication 2 error
I311, LCD communication reception error
I321, LCD communication sending error
I411, expansion controller communication error
K014, battery relay node sticking
R024, wiper forward relay power supply short circuit
R034, Wiper reverse relay power supply short circuit
R054, Bucket limit relay power supply short circuit
R144, rotating and flashing left relay power supply short circuit
R164, automatic total speed stop AIS relay 2 power supply short circuit
R184, safety locking relay power supply short circuit
Z010, abnormal common rail pressure value
Z030, pump flow increase compensation value is abnormal
R044, sprinkler motor relay power supply short circuit
R134, rotating and flashing right relay power supply short circuit
R154, walking alarm relay power supply short circuit
R174, engine stop relay power supply short circuit
R214, safety relay power supply short circuit
Z020, abnormal fuel type identification value
Z040, hydraulic oil clogging alarm value is abnormal
If you want to know more about Kobelco excavator error codes and troubleshooting, just feel free to contact us at sales@aprilparts.com. We’re glad to help.