Kobelco SK200-8 Excavator Error Code (Electromechanical Hydraulic Controller)

Error Code Fault
A015 Engine adjustment (A adjustment) is not performed, or adjustment fails
A035 The unloading valve adjustment (C adjustment) is not performed, or the adjustment fails.
A055 The memory value of the forearm retraction adjustment data controller is incorrect.
A215 ROM adjustment data write data abnormality
A235 ROM timer data writing data abnormality
A255 Proportional valve adjustment data writing abnormality
B012 Abnormal output of boom rising low pressure sensor
B014 Boom rise low voltage sensor power supply dash
B022 The output of the lower pressure sensor of the boom is abnormal
B024 Boom lower voltage sensor power supply short circuit
B032 The output of the low-pressure sensor when the forearm is extended is abnormal.
B034 The small tube extends out and the low-voltage sensor power supply is short-circuited.
B042 The output of the low pressure sensor of forearm recovery is abnormal.
B044 Small arm recycling low voltage sensor power supply short circuit
B052 The output of the low pressure sensor of the bucket is abnormal.
B054 Digging bucket low voltage sensor power supply short circuit
B062 The output of the low pressure sensor of the bucket is abnormal.
B064 Short circuit in the power supply of low voltage sensor for excavation bucket
B072 Abnormal output of rotating low pressure sensor
B074 Rotary low voltage sensor power supply short circuit
B092 Abnormal output of right walking low pressure sensor
B094 Right walking low voltage sensor power supply short circuit
B102 Left walking low pressure sensor output abnormality
B104 Left walking low voltage sensor power supply short circuit
B112 Select position to detect low pressure sensor output abnormality
B114 Select position to detect low voltage sensor power supply short circuit
B162 P1 side optional low pressure sensor output abnormality
B164 P1 side optional low voltage sensor power supply short circuit
B172 P2 side optional low pressure sensor output abnormality
B174 P2 side optional low voltage sensor power supply short circuit
C012 P1 pump high pressure sensor output abnormality
C014 P1 pump high voltage sensor power supply short circuit
C022 P2 pump high pressure sensor output abnormality
A025 The pump proportional valve adjustment (B adjustment) is not performed, or the adjustment fails.
A045 Boom raising adjustment data controller memory value is incorrect
A065 The memory value of the forearm extension adjustment data controller is incorrect.
A225 ROM adjustment data writing error
A245 ROM timer data writing abnormality
B010 The boom rising low pressure sensor is larger than the normal range
B013 Boom rising low pressure sensor disconnected
B020 The lowering pressure sensor of the boom is larger than the normal range
B023 The lowering pressure sensor of the boom is disconnected
B030 The low pressure sensor when the forearm extends out is larger than the normal range.
B033 The low voltage sensor of the forearm is disconnected
B040 The forearm recovery low pressure sensor is larger than the normal range
B043 The low pressure sensor of forearm recovery is disconnected
B050 Bucket excavation low pressure sensor is larger than normal range
B053 Bucket excavation low pressure sensor disconnected
B060 The low pressure sensor of the bucket discharge is larger than the normal range.
B063 Bucket discharge low pressure sensor disconnected
B070 Rotating low pressure sensor is larger than normal range
B073 Rotary low pressure sensor disconnected
B090 The right walking low pressure sensor is larger than the normal range
B093 Right running low voltage sensor disconnected
B100 Left walking low pressure sensor is larger than normal range
B103 Left walking low voltage sensor disconnected
B110 Select position to detect low pressure sensor is larger than normal range
B113 Select position to detect low voltage sensor disconnection
B160 P1 side optional low pressure sensor is larger than normal range
B163 The optional low-voltage sensor on the P1 side is disconnected
B170 P2 side optional low pressure sensor is larger than normal range
B173 The optional low-voltage sensor on the P2 side is disconnected
C010 P1 pump high pressure sensor is larger than normal range
C013 P1 pump high pressure sensor disconnected
C020 P2 pump high pressure sensor is larger than normal range
C023 P2 pump high pressure sensor disconnected
C024 P2 pump high voltage sensor power supply short circuit
C032 Abnormal output of the high pressure sensor of the boom head
C034 Big arm head high voltage sensor power supply short circuit
C042 Abnormal high-voltage sensor output of boom
C044 Boom high voltage sensor power supply short circuit
D013 P1 unloading proportional valve is disconnected
D023 P2 unloading proportional valve is disconnected
D033 Direct travel proportional valve disconnected
D063 The arm recovery 2-speed proportional valve is disconnected
E013 P1 pump proportional valve disconnected
E023 P2 pump proportional valve disconnected
F013 Work device booster solenoid switching valve transistor ON failure/disconnection
F023 Rotary brake electromagnetic switching valve transistor ON failure/disconnection
F031 Travel 1-2 speed solenoid switching valve transistor 0N fault/short circuit to ground
F041 Option selection solenoid switching valve transistor ON failure/short to ground
G042 The input speed of the electromechanical controller and the data received by the engine exceed the limits.
G043 The input speed of the electromechanical controller and the data received by the engine are disconnected.
H023 Big arm angle potentiometer disconnected
H024 Big arm angle potentiometer power supply short circuit
H091 Fuel sensor ground short circuit abnormality
H094 Fuel sensor potentiometer supply short circuit
1713 CAN1 communication reception abnormality (contact interrupted)
1313 Instrument cluster communication reception abnormality (contact interruption failure)
R014 Wiper arc prevents relay power from shorting
R034 Wiper reversal relay power supply short circuit
R054 Bucket limit relay power supply short circuit
R144 Left rotating flash light relay power supply short circuit
R164 Automatic idle stop AIS relay 2 power supply short circuit
R184 Operating lever lock relay power short circuit
C030 The high pressure sensor at the head of the boom is larger than the normal range
C033 Big arm head high pressure sensor disconnected
C040 The high pressure sensor of the boom is larger than the normal range
C043 Big boom high pressure sensor disconnected
D012 P1 unloading proportional valve transistor ON failure
D022 P2 unloading proportional valve transistor ON failure
D032 Direct travel proportional valve transistor ON failure
D062 Arm recovery 2-speed proportional valve transistor 0N failure
E012 P1 pump proportional valve transistor ON failure
E022 P2 pump proportional valve transistor ON failure
F011 Working device booster solenoid switching valve transistor O failure/short circuit to ground
F021 Rotary brake solenoid switching valve transistor O fault/short to ground
F033 Travel 1-2 speed solenoid switching valve transistor 0N fault/disconnection
F043 Option selection solenoid switching valve transistor 0N failure/disconnection
G032 The speed sensor directly input by the electromechanical controller exceeds the limit.
G033 The speed sensor directly input by the electromechanical controller is disconnected abnormally.
H013 Throttle potentiometer disconnected
H014 Throttle potentiometer power supply short circuit
H033 Broken wire of forearm angle potentiometer
H034 Forearm angle potentiometer power supply short circuit
H093 Fuel sensor potentiometer broken wire
1111 CAN1 communication reception abnormality (passive fault)
1311 Communication group CAN error
K014 Battery relay contact sintering
R024 Wiper forward relay power supply short circuit
R044 Sprinkler motor relay power supply short circuit
R134 Right rotating flash light relay power supply short circuit
R154 Walking buzzer, relay power supply short circuit
R174 Engine stop relay power supply short circuit
R214 Safety relay power supply short circuit

Kobelco SK200-8 Excavator Error Code(Hino J05 Engine)

Error Code Fault
P2228 Barometric pressure sensor failure (low)
P0192 Common rail pressure sensor failure (low)
P0191 Common rail pressure sensor failure
P0108 Boost pressure sensor failure (high)
P0118 Water temperature sensor failure (high)
P0183 Fuel temperature sensor failure (high)
P0340 Auxiliary speed sensor system failure
P2122 Throttle sensor 1 fault (low)
P2127 Throttle sensor 2 fault (low)
P1133 Emergency throttle sensor failure (high)
P0540 Preheating device failure (association power supply short circuit)
P0686 Main relay system failure
P0628 Transfer pump solenoid valve system failure (full discharge mode)
P2635 Transmission pump solenoid stuck
P1211 Injector solenoid valve drive system common 1 fault (short circuit to ground)
P1212 Injector solenoid valve drive system common 1 fault (power supply short circuit, open)
P0201 Injector 1 solenoid valve system disconnected
P0203 Injector 3 solenoid valve system disconnected
P0263 Cylinder-to-cylinder correction error 1
P0269 Cylinder-to-cylinder correction error 3
P0489 EGR valve linear solenoid valve 1 failure (disconnection, short circuit to ground)
P0404 EGR valve stuck 1
P0405 EGR valve rise sensor 1 fault (high)
P0217 overheat
U1001 CAN communication interrupted (vehicle)
P0200 ECU charge 8 circuit defective (high)
P0606 CPU failure (hardware detection)
P1601 Injector multi-point correction abnormality
P2635 Transmission pump not functioning properly
P2229 Barometric pressure sensor failure (high)
P0193 Common rail pressure sensor failure (high)
P0237 Boost pressure sensor failure (low)
P0117 Water temperature sensor failure (low)
P0182 Fuel temperature sensor failure (low)
P0335 Main speed sensor system failure
P2120 Two throttle sensor system failures
P2123 Throttle sensor 1 fault (high)
P2128 Throttle sensor 2 fault (high)
P0540 Preheating device failure (open/short circuit to ground)
P0617 Start switch system failure
P0629 Transmission solenoid valve system failure (association power supply short circuit)
P2635 Transmission pump abnormal pressure history
P0088 Common rail pressure abnormality, control system
P1214 Injector solenoid valve drive system common 2 fault (short circuit to ground)
P1215 Injector solenoid valve drive system common 2 fault (power supply short circuit, open)
P0202 Injector 2 solenoid valve system disconnected
P0204 Injector 4 solenoid valve system disconnected
P0266 Cylinder-to-cylinder correction error 2
P0272 Cylinder-to-cylinder correction error 4
P0490 EGR valve linear solenoid valve 1 failure (VB short circuit)
P0405 EGR valve rise sensor 1 fault (low)
P0234 Turbo overboost
P0219 Engine over-rev
P0611 ECU charging circuit defective (low)
P0605 Flash ROM abnormality
P0607 CPU monitoring IC abnormality
P0088 Abnormal common rail pressure and pump overpressure transmission